- Location
- Pembroke Dock, Dyfed
- Main postcode district
- SA72
- Nearby (straight line)
- Milford Haven (4 miles), Haverfordwest (8 miles) and Carmarthen (30 miles)
- Visit pricing
- Agreed in writing before we attend
Loading bay servicing covers planned preventive maintenance of dock equipment at agreed intervals. An engineer checks, adjusts and lubricates doors, levellers, shelters, seals, restraints, traffic lights and lift tables, tests safety devices and records defects in a written report. Servicing supports, but is separate from, insurer inspections and the LOLER thorough examinations that some equipment needs.
Where does this fit at a dock in Pembroke Dock?
Food, chilled and pharmaceutical operations around Pembroke Dock often prefer servicing outside loading peaks, which can be arranged with the price agreed beforehand. Ahead of an insurer inspection, sites near Pembroke Dock can line up a service visit so routine defects are dealt with before the inspector attends.
Lift tables at warehouses in Pembroke Dock need a LOLER thorough examination regime alongside servicing, and the two can be scheduled to suit the operation.
When something stops working at a loading bay in Pembroke Dock, contact us with a description and, ideally, photos. We will confirm the cost of the visit in writing before booking anyone. If the engineer finds the problem goes further than expected, you receive a quote for the additional work and decide whether to proceed. Every visit is followed by a written report you can keep with your maintenance records.
What inspections does the law require for loading bay equipment?
Loading bay equipment is work equipment under the Provision and Use of Work Equipment Regulations 1998 (PUWER), so it must be maintained in a safe condition and inspected where deterioration could lead to danger. In Northern Ireland the equivalent is PUWER (Northern Ireland) 1999.
- Insurer inspections: engineering insurers commonly inspect dock levellers under PUWER at 12-month intervals. This is separate from servicing.
- Lift tables: scissor lift tables fall under LOLER 1998, or LOLER (Northern Ireland) 1999, with thorough examination at least every 12 months, every 6 months if they lift people, or to a written examination scheme.
- Levellers and LOLER: most levellers are treated under PUWER, but one designed or used to lift people may fall under LOLER. This depends on the equipment and how it is used; your insurer or competent person will confirm.
- Doors: regulation 18 of the Workplace (Health, Safety and Welfare) Regulations 1992, and the Northern Ireland 1993 equivalent, require fall-back and anti-trap protection, so these devices are tested at every service.
Our guide to dock leveller inspections under PUWER and LOLER explains what applies.
What does a loading bay service visit include?
A loading bay service visit includes checking, adjusting and lubricating each item, testing its safety devices and recording its condition. Typical checks by equipment type:
- Doors: springs, cables, balance, rollers, hinges, tracks, safety edges, photocells, fall-back devices, controls and manual operation.
- Levellers: hydraulic leaks and oil level, hoses, cylinders, lip and hinges, deck condition, toe guards, controls and the maintenance strut.
- Shelters and seals: curtains, frames, pads, covers, airbags and blowers.
- Restraints, lights and interlocks: engagement, sensors and the full interlock sequence.
- Bumpers and wheel guides: wear and fixings.
- Lift tables: toe guards, bellows, hydraulics, controls and gates.
Minor adjustments and lubrication are part of the service. Anything needing parts or more time is recorded and quoted as a repair, so you stay in control of spend.
The visit price is agreed before anyone attends. Parts and any extra work are quoted before they are fitted.
Checks made while we are on site
- Control panels, push buttons and emergency stops
- Anti-fall device on upward-opening doors
- Previous service and inspection records, where available
- Door panels, side seals and bottom rubbers
- Door springs, cables and drums for wear or damage
- Shelter curtains, frames and side pads for tears
Options to discuss
Lift table coordination
Servicing of scissor lift tables timed alongside the LOLER thorough examination regime set by your insurer or competent person, so defects are cleared before examination.
Annual service
One planned visit a year, suited to lightly used bays, covering checks, adjustment, lubrication, safety device testing and a written condition report for each item.
Which rules apply in Wales?
Sites in Pembroke Dock follow the rules for Wales. Forming a new opening or dock pit may need Building Regulations approval, and loading houses, canopies or new dock approaches can need planning permission from the local planning authority. We check what applies before any work starts, so any approvals are understood before the programme is fixed.
Questions about loading bay servicing in Pembroke Dock
What happens if the engineer finds the equipment unsafe?
If equipment is found to be unsafe, the engineer will tell you straight away and recommend that it is isolated and taken out of use until it is repaired. That is recorded in the written report. We then quote the repair so you can decide how to proceed. Keeping an unsafe door or leveller in service puts people at risk, so we will always raise it.
Can you take over our existing loading bay maintenance arrangement?
Yes. Send us a list of the equipment at your Pembroke Dock site, with makes, models and approximate ages if known, plus recent service or inspection reports. We will propose a planned maintenance schedule and price it per item per visit. The first visit records the condition of everything, so you have a clear starting point for future servicing.
What is the difference between servicing and a statutory inspection?
Servicing keeps equipment working: cleaning, adjusting, lubricating and replacing worn parts. A statutory inspection or thorough examination is a separate check by a competent person, often arranged through your engineering insurer. Dock levellers are commonly inspected under PUWER at 12-month intervals, and lift tables may need LOLER thorough examination, depending on the equipment and how it is used. Your insurer or competent person will confirm what applies.
What is included in the service price?
The service price covers checking, adjusting and lubricating each item, testing its safety devices and a written report. Parts and repair work are not included; they are quoted separately so you can decide what to approve. Minor adjustments made during the visit are part of the service.
How often should dock levellers be serviced?
Dock levellers on busy docks are commonly serviced twice a year, while lightly used levellers may only need an annual service. The right interval depends on usage, the manufacturer's instructions and your risk assessment. Insurer inspections and any LOLER examinations run on their own schedules.
Loading bay servicing near Pembroke Dock
The same survey, quote and repair service is available in towns around Pembroke Dock, such as Milford Haven (4 miles), Haverfordwest (8 miles) and Carmarthen (30 miles).
Other loading bay services in Pembroke Dock
Full guide to loading bay servicing · Everything we do in Pembroke Dock
Whether it is a new bay or a fault on an existing one, call us or request a quote for your site in Pembroke Dock.