Loading bay doors and dock equipment, UK-wideFree site survey for new docks and upgradesRepair visits priced before we attend
Call free 0800 088 6248
Repairs and servicing · Milford Haven

Loading bay servicing in Milford Haven

This page explains how we handle loading bay servicing for sites in Milford Haven: what we look at, how the work is organised and what to send us to get things moving.

Guide £85–£180 per item per visit ex VATVisit priced before we attendSA73
Location
Milford Haven, Dyfed
Main postcode district
SA73
Nearby (straight line)
Pembroke Dock (4 miles) and Haverfordwest (7 miles)
Visit pricing
Agreed in writing before we attend
Loading bay servicing, in short

Loading bay servicing covers planned preventive maintenance of dock equipment at agreed intervals. An engineer checks, adjusts and lubricates doors, levellers, shelters, seals, restraints, traffic lights and lift tables, tests safety devices and records defects in a written report. Servicing supports, but is separate from, insurer inspections and the LOLER thorough examinations that some equipment needs.

Where does this fit at a dock in Milford Haven?

Ahead of an insurer inspection, sites near Milford Haven can line up a service visit so routine defects are dealt with before the inspector attends. Distribution centres in Milford Haven running high trailer volumes commonly need twice-yearly servicing to keep springs, hydraulics and seals ahead of wear.

Mixed-age dock equipment at older sites in Milford Haven benefits from a first service that records the condition of every item and prioritises any repairs.

We do not turn up and then name a price. Every repair or service visit in Milford Haven is agreed in writing first, including what the charge covers. Sending photos of the damage, error codes or leaks helps us diagnose the problem before travelling and bring the likely parts. Any additional work found on the day is quoted for your approval before it starts. You then get a written report for your records.

What happens on site during a service visit?

During a service visit the engineer works through the dock bay by bay, taking each item out of use only while it is being checked. Most of the dock keeps working throughout.

  1. Agree the order: the engineer meets the dock manager and agrees which bays are released when.
  2. Isolate: each item is isolated and locked off, and levellers are propped before anyone works underneath.
  3. Service and test: checks, adjustments and safety device tests are carried out.
  4. Hand back: each bay is returned to use once tested, with any unsafe item left out of use and reported straight away.

It helps if you can provide an equipment list with asset numbers, previous service and insurer reports, a contact on the day, and bays released as agreed. Out-of-hours visits can be arranged where daytime access is difficult, at a price agreed beforehand.

What inspections does the law require for loading bay equipment?

Loading bay equipment is work equipment under the Provision and Use of Work Equipment Regulations 1998 (PUWER), so it must be maintained in a safe condition and inspected where deterioration could lead to danger. In Northern Ireland the equivalent is PUWER (Northern Ireland) 1999.

  • Insurer inspections: engineering insurers commonly inspect dock levellers under PUWER at 12-month intervals. This is separate from servicing.
  • Lift tables: scissor lift tables fall under LOLER 1998, or LOLER (Northern Ireland) 1999, with thorough examination at least every 12 months, every 6 months if they lift people, or to a written examination scheme.
  • Levellers and LOLER: most levellers are treated under PUWER, but one designed or used to lift people may fall under LOLER. This depends on the equipment and how it is used; your insurer or competent person will confirm.
  • Doors: regulation 18 of the Workplace (Health, Safety and Welfare) Regulations 1992, and the Northern Ireland 1993 equivalent, require fall-back and anti-trap protection, so these devices are tested at every service.

Our guide to dock leveller inspections under PUWER and LOLER explains what applies.

Guide price, Milford Haven
£85–£180 per item per visit, ex VAT

The visit price is agreed before anyone attends. Parts and any extra work are quoted before they are fitted.

Bay checks on a repair or service visit

  • Leveller toe guards and side skirting, where fitted
  • Traffic light function and interlock operation
  • Vehicle restraint engagement and its signal sequence
  • Anti-fall device on upward-opening doors
  • Safety edges, photocells and light curtains
  • Previous service and inspection records, where available

Options to discuss

High-use programme

More frequent visits for docks running several shifts or very high trailer numbers, with the interval agreed after reviewing the equipment and how it is used.

Lift table coordination

Servicing of scissor lift tables timed alongside the LOLER thorough examination regime set by your insurer or competent person, so defects are cleared before examination.

Planning, building control and safety law in Wales

Scissor lift tables and dock lifts in Wales can fall under LOLER, with thorough examination at least every 12 months, or every 6 months where people are lifted, depending on the equipment and its use. For sites in Milford Haven, your insurer or competent person will confirm the regime, and we check what applies before any work starts.

Questions about loading bay servicing in Milford Haven

How is a repair or service visit in Milford Haven priced?

Repair and service visits are chargeable, and the price is agreed in writing before anyone attends. For loading bay servicing, the guide budget is £85 to £180 per item per visit, excluding VAT. The exact figure depends on the fault, parts, access and timing. If the engineer finds further work on the day, it is quoted for your approval before it is carried out.

What happens if the engineer finds the equipment unsafe?

If equipment is found to be unsafe, the engineer will tell you straight away and recommend that it is isolated and taken out of use until it is repaired. That is recorded in the written report. We then quote the repair so you can decide how to proceed. Keeping an unsafe door or leveller in service puts people at risk, so we will always raise it.

What is the difference between servicing and a statutory inspection?

Servicing keeps equipment working: cleaning, adjusting, lubricating and replacing worn parts. A statutory inspection or thorough examination is a separate check by a competent person, often arranged through your engineering insurer. Dock levellers are commonly inspected under PUWER at 12-month intervals, and lift tables may need LOLER thorough examination, depending on the equipment and how it is used. Your insurer or competent person will confirm what applies.

Do you service equipment you did not install?

Yes. We service all the common types of loading bay door, leveller, shelter, seal, restraint and lift table, whoever installed them. The first visit records the condition of each item, which gives you a baseline for future planning. Older or obsolete items are flagged in the report so you can budget for them.

Is loading bay servicing the same as an insurer inspection?

No. Servicing is planned maintenance that keeps equipment working and safe, while an insurer inspection is an independent check, commonly every 12 months for levellers under PUWER. Many sites schedule a service shortly before each inspection, so routine defects are dealt with before the inspector attends.

Loading bay servicing near Milford Haven

Nearby places we cover, measured from Milford Haven, include Pembroke Dock (4 miles) and Haverfordwest (7 miles). Ask if your own town is missing.

Other loading bay services in Milford Haven

Full guide to loading bay servicing · Everything we do in Milford Haven

Whether it is a new bay or a fault on an existing one, call us or request a quote for your site in Milford Haven.

Call freeGet a quote