- Location
- Reigate, Surrey
- Main postcode district
- RH2
- Nearby (straight line)
- Redhill (2 miles), Horley (5 miles) and Dorking (6 miles)
- Survey and quote
- Free, with a fixed written quote
A roller shutter loading bay door is a door made from interlocking horizontal slats, called laths, that coil around a barrel in a box above the opening. Because it rolls up into a compact space, a shutter needs little headroom and no ceiling tracks, which suits older units, low-headroom openings and buildings with cranes, pipes or racking close above the door.
Where does this fit at a dock in Reigate?
Unheated stores and trade counters in Reigate can suit a single-skin steel shutter, giving a secure dock door at a lower cost than an insulated sectional door. Landlords refurbishing a vacant unit in Reigate may choose an insulated shutter where headroom is tight but a future tenant is likely to heat the building.
Every shutter we quote for a building in Reigate starts with a survey of the opening, the space above it and how often the door will run.
Keeping the dock running is usually the first concern, so we plan around it. After a free survey of your Reigate site and a written quote at a fixed price, we agree when each bay can be released and whether any work should happen out of hours. Specialist installation engineers working under our management then fit the equipment, and we test it and hand over the documentation before the bay goes back into use.
Which lath should I choose: single skin, insulated or aluminium?
Choose single-skin steel for unheated buildings where cost and strength matter most, insulated laths where the building is heated, and aluminium where weight or corrosion is the main concern.
- Single-skin steel: strong and economical, ideal for unheated stores, trade counters and secure external openings, but it offers little insulation.
- Insulated steel laths: twin-skin laths filled with foam improve thermal performance and reduce noise. The coil is larger, so the box above the opening is bigger.
- Aluminium laths: lighter and corrosion resistant, useful in coastal or washdown environments, and easier on the motor at large openings.
- Perforated or punched laths: let light and air through while keeping the opening secure, better suited to internal cages than external docks.
Lath gauge and profile matter too. Heavier gauges resist forklift knocks and wind better, and we specify them for wide or exposed openings.
How is a roller shutter fitted to an existing loading bay opening?
A roller shutter is fitted either behind the opening on the inside face or between the reveals, with guides fixed down each side and the barrel mounted on brackets above. Fitting usually takes a day or less per opening once the shutter is on site.
The work normally includes:
- Removing and disposing of the old door or shutter.
- Checking the lintel and reveals will take the fixings, and adding steel packers if not.
- Fixing the guides, brackets and barrel, then running the curtain onto the barrel.
- Fitting the motor, controls, safety edge and photocells on electric shutters.
- Setting limits, testing the safety brake and demonstrating the manual override.
You will need to clear the area inside the opening and take the bay out of use. An electric shutter also needs a suitable isolated power supply near the barrel, which we can include in the quote if one is not already there.
The same published guide range applies across England; access, out-of-hours working and site conditions are confirmed at the free survey.
What do we check at the survey?
- Drainage on recessed or sloping dock approaches
- Clear opening width and height for each door
- Power supply at each bay, including three-phase availability
- Wind exposure at the dock, which affects door and shelter choice
- Lighting inside trailers and at the dock face
- Bumper position and wear or damage on the dock face
Options to discuss
Electric operation with safety devices
An external or tubular motor with push-button controls, safety edge, photocells and a hand-chain override for use during a power cut.
Wind-resistant build
End locks, deeper guides and heavier gauge laths for wide or exposed openings where gusts could pull the curtain out of its guides.
Planning, building control and safety law in England
Sites in Reigate fall under the rules for England. Structural changes such as forming a new opening or a dock leveller pit may need Building Regulations approval, and external structures such as loading houses, canopies or new dock approaches can need planning permission from the local planning authority. We check what applies at survey and build any approvals into the plan.
Questions about roller shutter loading bay doors in Reigate
Will you deal with building control and planning for a project in Reigate?
We check at survey whether the work is likely to need approval. Forming a new opening or dock pit may need Building Regulations approval, a building warrant or building control approval, depending on the nation, and external structures such as loading houses can need planning permission. Where approval is needed, we explain what is involved, work with your designer or agent, and build it into the programme.
Can you work alongside our main contractor on a new build in Reigate?
Yes. For new warehouses and fit-outs, we can supply and install the dock package as part of a wider project, working to the main contractor's programme, site rules and permits. We will need drawings, dock levels and the programme, and we coordinate pit details, power supplies and door openings with the relevant trades before installation begins.
Which building and safety rules apply to a site in Reigate?
It depends on which UK nation the site is in. England and Wales use Building Regulations approval, Scotland uses building warrants and Northern Ireland uses building control approval from the council. Workplace safety is regulated by HSE in Great Britain and HSENI in Northern Ireland, and energy rules differ between nations. For your site in Reigate, we check what applies at survey and design to it.
Do roller shutters work on cold store docks?
Roller shutters are rarely used as the main door on a cold store dock, because even insulated laths do not hold temperature as well as a purpose-made cold store door. They can work as an outer security door in front of an insulated door, or at ambient bays on the same site.
How long does a new roller shutter take to arrive?
Shutters are made to measure, so the lead time depends on size, lath type and finish, and we confirm it in the written quote. The existing door stays in use until the new shutter is ready, and installation is then booked for a time that suits your operation.
Roller shutter loading bay doors near Reigate
The same survey, quote and repair service is available in towns around Reigate, such as Redhill (2 miles), Horley (5 miles) and Dorking (6 miles).
Other loading bay services in Reigate
Full guide to roller shutter loading bay doors · Everything we do in Reigate
Send a few photos of the dock and a short description of the problem, and we will come back to you about your Reigate site.
