- Location
- Loughborough, Leicestershire
- Main postcode district
- LE11
- Nearby (straight line)
- Mountsorrel (4 miles), Coalville (8 miles) and Castle Donington (8 miles)
- Visit pricing
- Agreed in writing before we attend
Loading bay servicing covers planned preventive maintenance of dock equipment at agreed intervals. An engineer checks, adjusts and lubricates doors, levellers, shelters, seals, restraints, traffic lights and lift tables, tests safety devices and records defects in a written report. Servicing supports, but is separate from, insurer inspections and the LOLER thorough examinations that some equipment needs.
What should sites in Loughborough consider?
Property managers looking after several units around Loughborough can use one servicing schedule and reporting format across every building they manage. When you take on a unit in Loughborough with no maintenance history, a baseline service report gives you a clear starting point for future planning.
Mixed-age dock equipment at older sites in Loughborough benefits from a first service that records the condition of every item and prioritises any repairs.
When something stops working at a loading bay in Loughborough, contact us with a description and, ideally, photos. We will confirm the cost of the visit in writing before booking anyone. If the engineer finds the problem goes further than expected, you receive a quote for the additional work and decide whether to proceed. Every visit is followed by a written report you can keep with your maintenance records.
What inspections does the law require for loading bay equipment?
Loading bay equipment is work equipment under the Provision and Use of Work Equipment Regulations 1998 (PUWER), so it must be maintained in a safe condition and inspected where deterioration could lead to danger. In Northern Ireland the equivalent is PUWER (Northern Ireland) 1999.
- Insurer inspections: engineering insurers commonly inspect dock levellers under PUWER at 12-month intervals. This is separate from servicing.
- Lift tables: scissor lift tables fall under LOLER 1998, or LOLER (Northern Ireland) 1999, with thorough examination at least every 12 months, every 6 months if they lift people, or to a written examination scheme.
- Levellers and LOLER: most levellers are treated under PUWER, but one designed or used to lift people may fall under LOLER. This depends on the equipment and how it is used; your insurer or competent person will confirm.
- Doors: regulation 18 of the Workplace (Health, Safety and Welfare) Regulations 1992, and the Northern Ireland 1993 equivalent, require fall-back and anti-trap protection, so these devices are tested at every service.
Our guide to dock leveller inspections under PUWER and LOLER explains what applies.
How much does loading bay servicing cost?
Loading bay servicing typically costs £85 to £180 per item per visit, excluding VAT, where an item is one door, leveller, shelter, restraint or lift table. Simple items such as a dock seal sit towards the lower end; high-speed doors and lift tables sit towards the top.
How the price is agreed:
- You send a list of equipment, with photos or asset labels if you have them.
- We agree the price per item and the visit schedule in writing before the first visit.
- Repairs found during a service are quoted separately and only done once you approve them.
What moves the price:
- Equipment type: powered doors, levellers and lift tables take longer than seals and lights.
- Number of items: larger sites spread travel and set-up across more items.
- Frequency: the number of visits a year.
- Timing: out-of-hours visits cost more.
- Location: remote and island sites carry travel costs, shown in advance.
VAT is added at the standard rate.
The visit price is agreed before anyone attends. Parts and any extra work are quoted before they are fitted.
Bay checks on a repair or service visit
- Safety edges, photocells and light curtains
- Shelter curtains, frames and side pads for tears
- Pit frame welds, platform cracks and structural damage
- Dock bumpers for missing rubber or loose fixings
- Vehicle restraint engagement and its signal sequence
- Previous service and inspection records, where available
Options to discuss
Twice-yearly service
Two visits a year, common for busy docks, so wear on springs, hydraulics and shelter curtains is caught before it causes a breakdown at a busy time.
Multi-site schedule
One schedule, price list and report format across several sites or units, suited to landlords, managing agents, 3PLs and multi-site operators.
Planning, building control and safety law in England
Workplace safety in England is regulated by HSE. For a loading bay in Loughborough, that means doors meeting regulation 18 of the Workplace (Health, Safety and Welfare) Regulations 1992, equipment maintained under PUWER and suitable safeguards against vehicles driving away too early. We check what applies before any work starts and design the bay accordingly.
Questions about loading bay servicing in Loughborough
What information helps before a repair visit?
Photos or a short video of the fault are the most useful thing you can send, along with the make and model from the data plate, a description of what happens when the equipment is operated and any error codes. For a site in Loughborough, also tell us about access, parking and site rules. With that, we can price the visit and bring the likely parts.
What happens if the engineer finds the equipment unsafe?
If equipment is found to be unsafe, the engineer will tell you straight away and recommend that it is isolated and taken out of use until it is repaired. That is recorded in the written report. We then quote the repair so you can decide how to proceed. Keeping an unsafe door or leveller in service puts people at risk, so we will always raise it.
What is the difference between servicing and a statutory inspection?
Servicing keeps equipment working: cleaning, adjusting, lubricating and replacing worn parts. A statutory inspection or thorough examination is a separate check by a competent person, often arranged through your engineering insurer. Dock levellers are commonly inspected under PUWER at 12-month intervals, and lift tables may need LOLER thorough examination, depending on the equipment and how it is used. Your insurer or competent person will confirm what applies.
Do you service equipment you did not install?
Yes. We service all the common types of loading bay door, leveller, shelter, seal, restraint and lift table, whoever installed them. The first visit records the condition of each item, which gives you a baseline for future planning. Older or obsolete items are flagged in the report so you can budget for them.
Is loading bay servicing the same as an insurer inspection?
No. Servicing is planned maintenance that keeps equipment working and safe, while an insurer inspection is an independent check, commonly every 12 months for levellers under PUWER. Many sites schedule a service shortly before each inspection, so routine defects are dealt with before the inspector attends.
Loading bay servicing near Loughborough
Distances are measured from Loughborough. Nearby towns we cover include Mountsorrel (4 miles), Coalville (8 miles) and Castle Donington (8 miles), and other towns in the area are covered too.
Other loading bay services in Loughborough
Full guide to loading bay servicing · Everything we do in Loughborough
For a written price on loading bay work in Loughborough, request a quote and include photos of the bay if you can.