Loading bay doors and dock equipment, UK-wideFree site survey for new docks and upgradesRepair visits priced before we attend
Call free 0800 088 6248
Loading bay doors · Tiverton

Cold store dock doors in Tiverton

Warehouse, factory and trade sites in Tiverton can bring requests for cold store dock doors to us, and we organise the work in a way that suits how the site operates.

Guide £4,800–£9,500 per door ex VATFree site surveyEX16
Location
Tiverton, Devon
Main postcode district
EX16
Nearby (straight line)
Exeter (12 miles), Taunton (19 miles) and Exmouth (20 miles)
Survey and quote
Free, with a fixed written quote
Cold store dock doors, in short

A cold store dock door is an insulated loading bay door built for chilled or frozen buildings, usually a sectional door with thick insulated panels or a high-speed door with an insulated curtain. It differs from a standard dock door in its thermal breaks, extra seals and, on freezer docks, heating in the frame or seals so that ice cannot lock the door shut or tear the seals.

How does this suit sites in Tiverton?

Any cold store dock survey in Tiverton is carried out with the store running, so we can see ice, seals and traffic as they really are. Food manufacturers in Tiverton moving finished product into frozen storage need doors that resist ice and close quickly behind each forklift or trailer movement.

A chilled distribution centre in Tiverton opens its dock doors many times a shift, so the door specification matters far more than at an ambient bay.

Our part of the job in Tiverton is to survey, quote and manage; the fitting itself is done by specialist installation engineers working under our management. The survey and the written quote are free. Once the fixed price is accepted, we agree dates that work around your deliveries and shifts, including out-of-hours working where needed. Every installation is tested before handover, and you receive the documentation for each item fitted.

How can a cold store door be replaced without losing temperature?

A cold store door can be replaced with very little temperature loss if the work is planned around the store, with the opening screened and the fitting done in one continuous visit.

On a live cold store we usually:

  • schedule the work for the quietest period, often overnight or at a weekend,
  • fit a temporary insulated screen or strip curtain while the opening is exposed,
  • remove ice from the old frame and threshold before fixing the new door,
  • pre-assemble as much as possible so the opening is exposed for the shortest time.

From your side we need product moved back from the opening, any site permits for working in cold areas, and power for the operator and frame heaters. Heated frames typically need their own supply, which we set out in the quote. Our cold store loading bays guide covers planning the work in more depth.

Do cold store dock doors have to meet building regulations?

Yes, a new or replacement cold store dock door is still a vehicle access door, so building energy rules apply alongside workplace safety law and product standards.

  • England: Approved Document L (2021) Volume 2 limits the U-value of vehicle access and similar large doors to 1.3 W/m²K in new and replacement work. Cold store doors are normally specified to perform better than that to protect the store.
  • Wales, Scotland and Northern Ireland: Approved Document L for Wales, Section 6 of the Scottish Building Standards Technical Handbook and Technical Booklet F2 in Northern Ireland apply. We confirm the figure for your nation and project.
  • Power failure: under the Workplace (Health, Safety and Welfare) Regulations 1992 in Great Britain, or the 1993 Northern Ireland regulations, a powered door must be operable by hand where needed for health or safety, unless it opens automatically when power fails.
  • Standards: BS EN 13241 for the door and BS EN 12453 for powered operation.
Guide price, Tiverton
£4,800–£9,500 per door, ex VAT

The same published guide range applies across England; access, out-of-hours working and site conditions are confirmed at the free survey.

Survey checklist for your dock

  • Forklift and pallet truck loads crossing the leveller platform
  • Wall and steel structure for door, shelter and bumper fixings
  • Yard gradient and the slope of the approach to the dock
  • Escape routes and pedestrian doors close to the bay
  • Gaps around trailers where heated or chilled air escapes
  • How often each door cycles during a typical shift

Options to discuss

Dock interlocks

Controls that link the door to the shelter, leveller and restraint so the door only opens when a trailer is docked and sealed against the building.

Insulated high-speed door

A fast door with an insulated curtain for busy openings between temperature zones, where cutting open time matters more than maximum insulation.

What do the rules in England mean for the work?

Workplace safety in England is regulated by HSE. For a loading bay in Tiverton, that means doors meeting regulation 18 of the Workplace (Health, Safety and Welfare) Regulations 1992, equipment maintained under PUWER and suitable safeguards against vehicles driving away too early. We check what applies at survey and design the bay accordingly.

Questions about cold store dock doors in Tiverton

What warranty comes with new loading bay equipment?

New equipment comes with the manufacturer's warranty, which varies by product. Our workmanship terms are set out in writing in the quote for your Tiverton site, so you can see what is covered before you commit. Check the warranty terms for any servicing conditions, and we can quote for planned maintenance once the installation is complete.

Can you work alongside our main contractor on a new build in Tiverton?

Yes. For new warehouses and fit-outs, we can supply and install the dock package as part of a wider project, working to the main contractor's programme, site rules and permits. We will need drawings, dock levels and the programme, and we coordinate pit details, power supplies and door openings with the relevant trades before installation begins.

How long does installation take at a site in Tiverton?

It depends on the equipment, the number of bays, the condition of the dock and whether any building or electrical work is needed. We agree a programme with you after the survey, setting out which bays are out of use and when. Larger jobs are usually phased so that part of the dock stays open, and out-of-hours working can be arranged.

Will a new door reduce our refrigeration load?

A better-sealed, better-insulated door that stays shut except when a trailer is docked reduces the warm air entering the store, which is a significant source of load at a cold store dock. We cannot promise a figure, because results depend on your store, traffic and the rest of the dock, but the mechanism is well understood.

Can a standard sectional door be used on a chilled dock?

A standard insulated sectional door can work on a chilled dock if its panels are thick enough and its seals are in good condition. For frozen docks it is not usually suitable, because it lacks the thermal breaks and frame heating needed to stop ice forming. We advise on the right specification after surveying the store.

Cold store dock doors near Tiverton

Looking beyond Tiverton? Our pages for Exeter (12 miles), Taunton (19 miles) and Exmouth (20 miles) describe the same loading bay services and how to get in touch.

Other loading bay services in Tiverton

Full guide to cold store dock doors · Everything we do in Tiverton

If a loading bay in Tiverton needs attention, call us or send photos and details online.

Call freeGet a quote