- Location
- Dunstable, Bedfordshire
- Main postcode district
- LU6
- Nearby (straight line)
- Luton (5 miles), Leighton Buzzard (6 miles) and Harpenden (9 miles)
- Survey and quote
- Free, with a fixed written quote
A roller shutter loading bay door is a door made from interlocking horizontal slats, called laths, that coil around a barrel in a box above the opening. Because it rolls up into a compact space, a shutter needs little headroom and no ceiling tracks, which suits older units, low-headroom openings and buildings with cranes, pipes or racking close above the door.
Where does this fit at a dock in Dunstable?
Low headroom is the deciding factor at many older buildings, whether in Dunstable or elsewhere, and a compact roller shutter avoids overhead tracks altogether. Docks that face an open yard in Dunstable can catch strong gusts, so we check orientation and specify end locks and heavier laths where exposure calls for it.
Landlords refurbishing a vacant unit in Dunstable may choose an insulated shutter where headroom is tight but a future tenant is likely to heat the building.
Your loading bay stays our responsibility from the survey to the handover. In Dunstable, the survey and written quote are free, and the quoted price is fixed for the agreed scope. Installation is carried out by specialist engineers working under our management, at times planned with you to protect your loading schedule. Out-of-hours work is available by arrangement. We finish by testing the equipment and handing over its documentation.
How much does a roller shutter loading bay door cost?
A roller shutter loading bay door typically costs £1,600 to £4,800 per door, excluding VAT, supply and fit. That usually makes it the most economical door for a dock opening, though the specification makes a big difference to where a door lands.
The price depends mainly on:
- Size: wider openings need a larger barrel, heavier laths and stronger brackets.
- Lath type: single-skin steel is the cheapest; foam-filled insulated laths and aluminium cost more.
- Operation: hand chain, or an electric motor with controls, safety edge and photocells.
- Wind resistance: end locks, deeper guides or heavier gauge laths for exposed openings.
- Finish: galvanised steel or a powder-coated colour, plus a hood box to protect the coil.
- Site work: stripping out an old shutter, repairing reveals, providing power and working out of hours.
The written quote that follows our free site survey fixes the price for the work described.
Is a roller shutter or a sectional door better for a loading bay?
A roller shutter is usually better where headroom is tight, budgets are limited or the building is unheated, while a sectional door is usually better for heated buildings and busy docks that open and close all day.
- Headroom: a shutter coils into a box above the opening; a sectional door needs track running back under the ceiling or up the wall.
- Insulation: insulated sectional panels generally outperform insulated laths.
- Speed: shutters are slower to open and close than most electric sectional doors.
- Security: a closed steel shutter is a robust barrier.
- Repairs: damaged laths can be replaced individually, just as a dented sectional panel can be swapped.
See sectional loading bay doors to compare the two. Where either would work, we can quote both so you can weigh price against performance.
The same published guide range applies across England; access, out-of-hours working and site conditions are confirmed at the free survey.
What do we check at the survey?
- Gaps around trailers where heated or chilled air escapes
- Yard gradient and the slope of the approach to the dock
- Power supply at each bay, including three-phase availability
- Forklift and pallet truck loads crossing the leveller platform
- Clear opening width and height for each door
- Wheel guide positions and yard markings for reversing vehicles
Options to discuss
Aluminium shutter
Lighter laths that resist corrosion, suited to coastal sites, washdown areas and large openings where a lighter curtain puts less strain on the motor.
Electric operation with safety devices
An external or tubular motor with push-button controls, safety edge, photocells and a hand-chain override for use during a power cut.
Which rules apply in England?
Sites in Dunstable fall under the rules for England. Structural changes such as forming a new opening or a dock leveller pit may need Building Regulations approval, and external structures such as loading houses, canopies or new dock approaches can need planning permission from the local planning authority. We check what applies at survey and build any approvals into the plan.
Questions about roller shutter loading bay doors in Dunstable
What details do you need from us to quote for roller shutter loading bay doors?
To get started, send the site address in Dunstable, the number of bays or openings, approximate sizes, and photos of the dock from inside and outside. Tell us what vehicles you load, what goods you handle and any temperature requirements. Drawings help on new builds. We then arrange the free survey and confirm the details before the written quote is issued.
Can you work outside our normal operating hours in Dunstable?
Yes, by arrangement. Evening, night and weekend working can be planned so the installation causes as little disruption as possible to your loading schedule. Out-of-hours work can affect the price, so mention it at the survey and we will include it in the written quote. The agreed times are confirmed in the programme before the job starts.
Will you deal with building control and planning for a project in Dunstable?
We check at survey whether the work is likely to need approval. Forming a new opening or dock pit may need Building Regulations approval, a building warrant or building control approval, depending on the nation, and external structures such as loading houses can need planning permission. Where approval is needed, we explain what is involved, work with your designer or agent, and build it into the programme.
Can an existing manual shutter be motorised?
Often yes. If the barrel, end plates and curtain are in good condition, an external or tubular motor can be added with controls and safety devices. Older or heavier shutters sometimes need a stronger barrel first, and a badly worn curtain is usually better replaced at the same time.
Do roller shutters work on cold store docks?
Roller shutters are rarely used as the main door on a cold store dock, because even insulated laths do not hold temperature as well as a purpose-made cold store door. They can work as an outer security door in front of an insulated door, or at ambient bays on the same site.
Roller shutter loading bay doors near Dunstable
If your site is not in Dunstable itself, it may be near one of these: Luton (5 miles), Leighton Buzzard (6 miles) and Harpenden (9 miles). Pick the closest.
Other loading bay services in Dunstable
Full guide to roller shutter loading bay doors · Everything we do in Dunstable
Have photos of the door, leveller or shelter? Send them with your enquiry and we can give a clearer answer for your Dunstable site.