- Location
- Prescot, Merseyside
- Main postcode district
- L34
- Nearby (straight line)
- Huyton (2 miles), St Helens (3 miles) and Halewood (5 miles)
- Survey and quote
- Free, with a fixed written quote
A PVC strip curtain is a row of flexible, overlapping plastic strips hung from a rail across a doorway, so that people and vehicles can pass through while the strips fall back to close the gap behind them. At loading bays they hang behind the main door or across internal openings, reducing draughts, dust and temperature loss for much less than the cost of a powered door.
Why do sites in Prescot choose this?
Chilled rooms off a dock in Prescot can lose temperature through internal doorways, and a low-temperature strip curtain is a quick, inexpensive fix. In a warehouse in Prescot where doors stay open for much of the shift, strip curtains offer a practical first step before considering a high-speed door.
Where strips at a site in Prescot have turned cloudy and scratched, replacing them restores visibility for drivers and pedestrians sharing the opening.
Step one is a survey at your site in Prescot, which costs nothing and carries no obligation. Step two is a written quote with a fixed price and a clear scope. Step three is installation, scheduled around your operation and carried out by specialist installation engineers working under our management, including evenings or weekends if agreed. Step four is handover, when the equipment is tested in front of you and the paperwork is passed over.
How often do PVC strips need replacing?
PVC strips need replacing when they become scratched, cloudy, split or shortened, and how often that happens depends almost entirely on traffic. A curtain at a busy forklift opening wears far faster than one at a quiet pedestrian door.
Signs that strips are due for replacement:
- You can no longer see clearly through them.
- Strips have torn at the top fixing or split along their length.
- Gaps have opened because strips have shrunk or been cut short.
- Low-temperature strips have stiffened and no longer fall back into place.
Individual strips can be swapped without replacing the whole curtain, which keeps costs down. Cleaning with a mild detergent helps visibility, while solvents can damage the PVC. Moving strips from the busy centre to the edges, and back, spreads the wear more evenly.
Which strip width, thickness and grade should I choose?
Choose the strip size by the size of the opening and the traffic through it, and the grade by temperature and use. Wider, thicker strips seal better and resist forklifts, but are heavier to push through on foot.
- Pedestrian doorways: typically 200 mm wide by 2 mm thick strips with a modest overlap.
- Forklift openings: typically 300 mm wide by 3 mm thick, with a larger overlap.
- Large dock openings: typically 400 mm wide by 4 mm thick, which hang well in draughts.
- Low-temperature grade: stays flexible in chillers and freezers, where standard PVC would stiffen and crack.
- Ribbed strips: raised ribs take the wear from forklifts and keep the strips clearer for longer.
- Specialist grades: anti-static, tinted or opaque, or welding grade for screening.
Overlap matters as much as thickness. A full overlap gives a better seal in cold or dusty areas, while a partial overlap is easier to walk through.
The same published guide range applies across England; access, out-of-hours working and site conditions are confirmed at the free survey.
What does the free survey cover?
- Age and condition of the equipment already in place
- Headroom above the opening and which track type will suit it
- Asbestos register and any other site hazard information
- Gaps around trailers where heated or chilled air escapes
- Forklift and pallet truck loads crossing the leveller platform
- Lighting inside trailers and at the dock face
Options to discuss
Standard clear strips
Clear flexible PVC for ambient warehouses and goods-in areas, giving good visibility and draught control at pedestrian and forklift openings.
Ribbed strips
Strips with raised ribs that take the abrasion from forklifts and pallets, helping them stay clearer for longer at busy openings.
Planning, building control and safety law in England
Sites in Prescot fall under the rules for England. Structural changes such as forming a new opening or a dock leveller pit may need Building Regulations approval, and external structures such as loading houses, canopies or new dock approaches can need planning permission from the local planning authority. We check what applies at survey and build any approvals into the plan.
Questions about PVC strip curtains in Prescot
How do you price PVC strip curtains for a site in Prescot?
Guide budgets for supply and fit are £180 to £1,100 per opening, excluding VAT. The figure moves with size, insulation, the operator, electrics, access, any pit or groundworks and out-of-hours working. Where levellers are involved, the guide assumes an existing, sound pit. After the free survey you receive a fixed written quote, and that is the price for the agreed scope.
Is the site survey in Prescot free?
Yes. For new installations, replacements, upgrades, conversions and complete bays, the site survey and written quote are free and come with no obligation. The survey lets us measure the openings, check the dock and structure, and understand how the bay is used, so the quote reflects your site. Repair and servicing visits are different: they are chargeable, with the price agreed before anyone attends.
Will you deal with building control and planning for a project in Prescot?
We check at survey whether the work is likely to need approval. Forming a new opening or dock pit may need Building Regulations approval, a building warrant or building control approval, depending on the nation, and external structures such as loading houses can need planning permission. Where approval is needed, we explain what is involved, work with your designer or agent, and build it into the programme.
Do strip curtains work at an external dock opening?
Yes, strip curtains are often hung just inside an external dock door to reduce draughts while the door is open for loading. They are not a substitute for the door itself, which still closes the opening for security and weather whenever the bay is not in use.
Can strips be replaced individually?
Yes, individual strips can be unhooked or unclamped and replaced without taking down the whole curtain. Keeping a few spare strips on site lets your team swap damaged ones as soon as they appear, which keeps visibility and sealing consistent across the opening.
PVC strip curtains near Prescot
Other towns within reach of Prescot on our coverage list include Huyton (2 miles), St Helens (3 miles) and Halewood (5 miles), all covered on the same terms.
Other loading bay services in Prescot
Full guide to PVC strip curtains · Everything we do in Prescot
Use the quote tool to tell us about the doors, levellers or shelters at your Prescot site, and we will be in touch to arrange the next step.
