- Location
- Lancing, West Sussex
- Main postcode districts
- BN15 and BN43
- Nearby (straight line)
- Shoreham-by-Sea (2 miles), Worthing (2 miles) and Portslade (5 miles)
- Survey and quote
- Free, with a fixed written quote
A cold store dock door is an insulated loading bay door built for chilled or frozen buildings, usually a sectional door with thick insulated panels or a high-speed door with an insulated curtain. It differs from a standard dock door in its thermal breaks, extra seals and, on freezer docks, heating in the frame or seals so that ice cannot lock the door shut or tear the seals.
What should sites in Lancing consider?
Converting an ambient unit in Lancing to chilled storage usually means replacing standard dock doors with insulated ones and sealing around the trailers. During warm, humid spells, any cold store dock in Lancing is most exposed to condensation and ice, which is why heated frames and good shelters are worth considering.
A chilled distribution centre in Lancing opens its dock doors many times a shift, so the door specification matters far more than at an ambient bay.
A single contact at Loading Bay Doors handles your project in Lancing from start to finish. The free site survey and fixed written quote come first, with no obligation to proceed. We then book the installation for times that suit the operation, including out of hours by arrangement, and manage the specialist engineers on site. At the end we commission and test the equipment, walk your team through it and provide the documentation.
Do cold store dock doors have to meet building regulations?
Yes, a new or replacement cold store dock door is still a vehicle access door, so building energy rules apply alongside workplace safety law and product standards.
- England: Approved Document L (2021) Volume 2 limits the U-value of vehicle access and similar large doors to 1.3 W/m²K in new and replacement work. Cold store doors are normally specified to perform better than that to protect the store.
- Wales, Scotland and Northern Ireland: Approved Document L for Wales, Section 6 of the Scottish Building Standards Technical Handbook and Technical Booklet F2 in Northern Ireland apply. We confirm the figure for your nation and project.
- Power failure: under the Workplace (Health, Safety and Welfare) Regulations 1992 in Great Britain, or the 1993 Northern Ireland regulations, a powered door must be operable by hand where needed for health or safety, unless it opens automatically when power fails.
- Standards: BS EN 13241 for the door and BS EN 12453 for powered operation.
How does a cold store door work with the shelter and leveller?
On a cold store dock the door, shelter and leveller should work as one system, with the door opening only once the trailer is sealed against the building and closing before the seal is released.
A typical sequence is:
- The trailer reverses onto the bumpers and is held by a restraint, or the driver's keys are taken.
- The shelter inflates or the seal compresses around the trailer.
- The door opens and the leveller lip is lowered onto the trailer bed.
- Loading takes place inside a sealed link between store and trailer.
- The leveller is stored, the door closes, then the shelter releases.
Interlocks make this sequence automatic, so the door cannot be left open with no trailer present. Insulated leveller platforms and seals around the pit also reduce cold loss through the floor of the bay.
The same published guide range applies across England; access, out-of-hours working and site conditions are confirmed at the free survey.
What do we check at the survey?
- Wind exposure at the dock, which affects door and shelter choice
- Temperature requirements for chilled, frozen or ambient goods
- Escape routes and pedestrian doors close to the bay
- Clear opening width and height for each door
- How often each door cycles during a typical shift
- Wall and steel structure for door, shelter and bumper fixings
Options to discuss
Heated frames and seals
Low-power heating in the side frames, bottom seal or threshold that keeps contact surfaces above freezing so the door does not ice up or tear its seals.
Insulated sectional cold store door
Thick insulated panels with thermal breaks and full perimeter seals, the usual choice for chilled and frozen external dock openings that also need to be secure overnight.
Regulations and approvals in England
In England, Approved Document L (2021) sets a limiting U-value of 1.3 W/m²K for vehicle access and similar large doors in new and replacement work. That shapes door specification for sites in Lancing, so we confirm the requirement for your project and check what applies at survey before recommending a door.
Questions about cold store dock doors in Lancing
Do you remove and dispose of the old equipment?
Yes, where it is part of the scope. When we replace doors, levellers, shelters or seals at a site in Lancing, removal and disposal of the old equipment can be included and is itemised in the quote, so it is clear what is covered. If anything should be kept, such as a frame or motor that is still serviceable, we agree that at survey.
What warranty comes with new loading bay equipment?
New equipment comes with the manufacturer's warranty, which varies by product. Our workmanship terms are set out in writing in the quote for your Lancing site, so you can see what is covered before you commit. Check the warranty terms for any servicing conditions, and we can quote for planned maintenance once the installation is complete.
Can you work alongside our main contractor on a new build in Lancing?
Yes. For new warehouses and fit-outs, we can supply and install the dock package as part of a wider project, working to the main contractor's programme, site rules and permits. We will need drawings, dock levels and the programme, and we coordinate pit details, power supplies and door openings with the relevant trades before installation begins.
Can a cold store door be paired with a high-speed door?
Yes, cold store docks often pair an insulated sectional door on the outside with a fast door just inside it, or use an insulated high-speed door as the only door between zones. The right arrangement depends on traffic, security and how much space there is around the opening.
Will a new door reduce our refrigeration load?
A better-sealed, better-insulated door that stays shut except when a trailer is docked reduces the warm air entering the store, which is a significant source of load at a cold store dock. We cannot promise a figure, because results depend on your store, traffic and the rest of the dock, but the mechanism is well understood.
Cold store dock doors near Lancing
Distances are measured from Lancing. Nearby towns we cover include Shoreham-by-Sea (2 miles), Worthing (2 miles) and Portslade (5 miles), and other towns in the area are covered too.
Other loading bay services in Lancing
Full guide to cold store dock doors · Everything we do in Lancing
Ready to talk about a loading bay in Lancing? Call us, or send the details through the quote form.