- Location
- Earl Shilton, Leicestershire
- Main postcode district
- LE9
- Nearby (straight line)
- Hinckley (4 miles), Nuneaton (7 miles) and Leicester (9 miles)
- Survey and quote
- Free, with a fixed written quote
A cold store dock door is an insulated loading bay door built for chilled or frozen buildings, usually a sectional door with thick insulated panels or a high-speed door with an insulated curtain. It differs from a standard dock door in its thermal breaks, extra seals and, on freezer docks, heating in the frame or seals so that ice cannot lock the door shut or tear the seals.
Where does this fit at a dock in Earl Shilton?
Any cold store dock survey in Earl Shilton is carried out with the store running, so we can see ice, seals and traffic as they really are. For a packhouse in Earl Shilton handling fresh produce, a well-sealed chilled dock door helps keep warm air out of the store once produce has been cooled.
When an older cold store in Earl Shilton has a door that has been repaired many times, a planned replacement can be timed for a quieter trading period.
Your loading bay stays our responsibility from the survey to the handover. In Earl Shilton, the survey and written quote are free, and the quoted price is fixed for the agreed scope. Installation is carried out by specialist engineers working under our management, at times planned with you to protect your loading schedule. Out-of-hours work is available by arrangement. We finish by testing the equipment and handing over its documentation.
How can a cold store door be replaced without losing temperature?
A cold store door can be replaced with very little temperature loss if the work is planned around the store, with the opening screened and the fitting done in one continuous visit.
On a live cold store we usually:
- schedule the work for the quietest period, often overnight or at a weekend,
- fit a temporary insulated screen or strip curtain while the opening is exposed,
- remove ice from the old frame and threshold before fixing the new door,
- pre-assemble as much as possible so the opening is exposed for the shortest time.
From your side we need product moved back from the opening, any site permits for working in cold areas, and power for the operator and frame heaters. Heated frames typically need their own supply, which we set out in the quote. Our cold store loading bays guide covers planning the work in more depth.
How much does a cold store dock door cost?
A cold store dock door typically costs £4,800 to £9,500 per door, excluding VAT, supply and fit. Chilled docks usually sit lower in that range than freezer docks, because freezer doors need more insulation and frame heating.
Price is mainly driven by:
- Operating temperature: chilled, frozen, or a door between two temperature zones.
- Door type: insulated sectional, insulated high-speed, or both at one opening.
- Heating: heated frames, heated bottom seals or threshold heating to stop ice forming.
- Panel thickness and thermal breaks: thicker panels and better breaks reduce condensation and heat gain.
- Controls: faster operators, interlocks with shelters and levellers, and automatic closing.
- Working conditions: installing in a live cold store often means out-of-hours work and temporary screening.
We price each door after a free site survey, and the written quote fixes the cost.
The same published guide range applies across England; access, out-of-hours working and site conditions are confirmed at the free survey.
What do we check at the survey?
- Asbestos register and any other site hazard information
- Bumper position and wear or damage on the dock face
- Working hours, shift patterns and windows for out-of-hours work
- Gaps around trailers where heated or chilled air escapes
- Condition of any existing leveller pit, kerb angles and pit drainage
- Scope to convert ground-level doors into docks or add lift tables
Options to discuss
Heated frames and seals
Low-power heating in the side frames, bottom seal or threshold that keeps contact surfaces above freezing so the door does not ice up or tear its seals.
Dock interlocks
Controls that link the door to the shelter, leveller and restraint so the door only opens when a trailer is docked and sealed against the building.
Which rules apply in England?
In England, Approved Document L (2021) sets a limiting U-value of 1.3 W/m²K for vehicle access and similar large doors in new and replacement work. That shapes door specification for sites in Earl Shilton, so we confirm the requirement for your project and check what applies at survey before recommending a door.
Questions about cold store dock doors in Earl Shilton
What details do you need from us to quote for cold store dock doors?
To get started, send the site address in Earl Shilton, the number of bays or openings, approximate sizes, and photos of the dock from inside and outside. Tell us what vehicles you load, what goods you handle and any temperature requirements. Drawings help on new builds. We then arrange the free survey and confirm the details before the written quote is issued.
Do you remove and dispose of the old equipment?
Yes, where it is part of the scope. When we replace doors, levellers, shelters or seals at a site in Earl Shilton, removal and disposal of the old equipment can be included and is itemised in the quote, so it is clear what is covered. If anything should be kept, such as a frame or motor that is still serviceable, we agree that at survey.
Which building and safety rules apply to a site in Earl Shilton?
It depends on which UK nation the site is in. England and Wales use Building Regulations approval, Scotland uses building warrants and Northern Ireland uses building control approval from the council. Workplace safety is regulated by HSE in Great Britain and HSENI in Northern Ireland, and energy rules differ between nations. For your site in Earl Shilton, we check what applies at survey and design to it.
What happens to a cold store door in a power cut?
In a power cut the door stops where it is and the frame heating switches off, so it must be possible to operate the door by hand. Powered dock doors normally have a hand chain, crank or release for this. We show your team how to use it at handover so the store can be closed up quickly.
Do heated door frames use a lot of power?
Frame and seal heaters are low-power elements designed to keep surfaces just above freezing rather than to heat the dock. Many can be controlled by a thermostat so they only run when needed. We set out the supply required in the written quote so it can be planned before installation.
Cold store dock doors near Earl Shilton
Other towns within reach of Earl Shilton on our coverage list include Hinckley (4 miles), Nuneaton (7 miles) and Leicester (9 miles), all covered on the same terms.
Other loading bay services in Earl Shilton
Full guide to cold store dock doors · Everything we do in Earl Shilton
Send a few photos of the dock and a short description of the problem, and we will come back to you about your Earl Shilton site.